Quotations are hereby invited for the Removal of, repairs to, supply and installation of electrical services on the 2nd to 6th floor of annex building – DHA Church Square Facility. Service requirements: a) Remove all existing light fittings and replace with new in Office areas, Bathrooms and Kitchens; b) Repair, where necessary, and install new light switches in Office Areas, Bathrooms and Kitchens; c) Remove all electrical wiring from existing DB’s; d) Supply and install new P9000 channel in ceiling void to establish wire way for the entire floor, to suit furniture layout, inclusive of all fittings, fixings, bends, tees, and elbows; e) Supply and install new wire mesh basket, medium duty inclusive of all fittings, fixings, bends, tees, and elbows; f) Supply and install new double tier power skirting inclusive of all fittings, fixings, bends, tees, and elbows; g) Supply and install PVC conduit inclusive of all fittings, fixings, bends, tees, and elbows; h) Supply and install socket outlet including cover for power skirting, 16A, single SSO, White; i) Supply and install socket outlet including cover for power skirting, 16A, single SSO dedicated outlet, Red; j) Network point including 30m of cat 5 cable; k) Supply and install new triple pole isolators, inclusive of fixings and fittings; l) Supply and install new single pole isolators, inclusive of fixings and fittings; m) Supply and install new GRP wire 1.5 mm; n) Supply and install new GRP wire 2.5 mm; o) Supply and install new GRP wire 4 mm; p) Supply and install new SWA cable, including all terminations, 25 mm 4 core; q) Supply and install new SWA cable, including all terminations, 10 mm 4 core; r) Supply and install new triple pole circuit breaker 10-60A 5kA; s) Supply and install new single pole circuit breaker 1-30A 5kA; t) Supply and install new two compartment UPS DB inclusive of circuit breakers and blanks, fed from emergency power supply; u) Service existing DB on floor; v) Testing and issuing of COC for Floor DB and UPS DB; w) Labelling of all power and data outlets; x) Major Service for existing 450 kVA generator; y) Service of existing LV panels in basement; z) Service of existing DB’s in basement. Please note that this quotation was published late. (Offerte №77616817it)

Registrati

Condividi:
Nazione: South Africa
Linguaggio: EN
Numero: 77616817
Data pubblicazione: 10-02-2023
Fonte:

Description

Tutte le informazioni sull'appalto sono chiuse.
Per ulteriori lavori con il sito, leggi le informazioni di seguito.

Chi siamo

Motore di ricerca leader per gare e acquisti in Russia e nel mondo

  • Il più grande database di appalti e fonti di approvvigionamento in Russia e nel mondo
  • Newsletter giornaliera gratuita secondo le tue impostazioni
  • Informazioni sui vincitori delle gare nel formato che ti serve
  • Comoda visualizzazione e caricamento delle informazioni

Scegli noi

Iniziare

Registrazione al sito, dopodiché sono disponibili le seguenti funzionalità del sito:

  • Iscriviti alle mailing list gratuite per le tue frasi chiave
  • Visualizza annunci di gara
  • Esporta informazioni di riepilogo in formato Excel
  • Visualizza parte delle informazioni sui vincitori, fornitori e clienti delle gare

Registrazione

Per utilizzare tutte le funzioni del sito e visualizzare tutte le informazioni, devi registrare un account commerciale

  • Tariffa selezionata
  • Paga per l'accesso in uno qualsiasi dei modi possibili

Accesso completo
Quotations are hereby invited for the following: Structural Building & Hardware Materials: Structural hardware: - 2 each x Abloy 57mm padlock protect 25mm; - 2 each x labour locksmithing master keyed padlock; - 2 each x key to code Abloy. Delivery Date: 2023/04/05, Delivery To: CS - Open Space & Nature Conservation CSON, Delivery Address: 1 CS - Open Space & Nature Conservation, Cape Town. Please note that this quotation was published late. Fonte: ONLINE TENDERS

Quotations are hereby invited for the following: Structural Building & Hardware Materials: Structural hardware: - 30 square meter x tiles 5.6m x 2.5m. Delivery Date: 2023/03/03, Delivery To: Merissa Goodwood office, Delivery Address: 263 Voortrekker Road, Cape Town. Please note that this quotation was published late. Fonte: ONLINE TENDERS

Tenders are hereby requested from competent and experienced contractors for the demolition of existing houses and the construction of new houses in Velddrif and Piketberg, as set out in the specifications. Fonte: ONLINE TENDERS

Quotations are hereby invited for the appointment of the service provider for the repairs and upgrading of lifts at annex building in Church Square, Pretoria. Service requirements: a) New Controller - including door zone light that works from battery. b) Shaft information - new shaft information required. New shaft harness. c) Overloads need to be fitted and working. Test will be done with consultant present. d) New encoder on main motor. e) Main motor and gearbox – Retain, sonar test (Schindler 3-point bearing system). f) Main brake - retain but ensure new controller voltage can accommodate existing. g) Surge protection unit with disconnect contactor. h) Brake release instructions. i) New trailing cable. j) New top of car control box including top of car led light. (According to new standards). k) Shaft lights - New with 60-watt LED spotlight top of shaft. l) Maintenance drive control in pit. m) Alarm button top of car and in pit required. n) New main ropes. o) Retain existing governor rope. p) New curtain of light car door sensor. q) Door drive – Existing, only interface. r) Bottom floor landing door to be able to be opened from the inside as per new standard. s) Emergency battery drive – Not required. On generator – Sequencer unit to be priced for to home one lift at a time and then the stretcher lift needs to remain in service. t) Signalization: • New buttons (micro stroke) car and landing including COP and Landing plates. • Display: New dot matrix including plates on COP and main floor, position height to be paraplegic friendly. • New COP the registration no to be engraved onto COP and LED emergency light. • Arrows and gongs on the rest of landings. (Position as per existing above landing door. Part 70. Buttons raised number, height above floor including beep on buttons when pressed. u) Voice annunciation required. v) 12 – months included free maintenance. w) Annex A and B required on completion. x) Allow for 10% for professional fees to include design, supervision, quality control and certification by registered professional engineer. Please note that this quotation was published late. Fonte: ONLINE TENDERS

Quotations are hereby invited for the Removal of, repairs to, supply and installation of HVAC services at the annex building – DHA Church Square Facility. Service requirements: a) Remove the existing VRF system, including condensers, indoor units, piping, drains, etc. on Floors 2 to 6. b) Replace existing VRF system with suitable air conditioning system on Floors 2 to 6. c) Remove and replace existing extract system from ablution and kitchen areas on Floors 2 to 6. d) Remove and replace fresh air supply system on Floors 2 to 6. e) Allow for electrical distribution for newly installed equipment, including installation in existing DB on floors 2 to 6. f) Allow for carnage cost to remove and replace existing condensers (1 x lift). g) Allow for 10% for professional fees to include design, supervision, quality control and certification by registered professional engineer. h) Allow for contingency. Fonte: ONLINE TENDERS

Re-advertisement: Tenders are hereby requested from competent and experienced service providers for the design, supply, install and commissioning of a hybrid system in various towns in Bergrivier Municipality as set out in the specifications. Fonte: ONLINE TENDERS