Re-Advertisement: Quotations are hereby invited for the following: Supply and delivery of reflectance targets. Specifications: - 2% target, width 500mm x height 500mm, colour 1 x 01 each; - 9% target, width 500mm x height 500mm, colour 1 x 01 each; - 23% target width 500mm x height 500mm, colour 1 x 01 each; - 46% target width500mm X height 500mm, colour 1 x 01 each. Place where goods, works or services are required: R573 and Moloto Road, Pretoria, 0001. (Offerte №94296383it)

Registrati

Condividi:
Nazione: South Africa
Linguaggio: EN
Numero: 94296383
Data pubblicazione: 15-11-2023
Fonte:

Description

Tutte le informazioni sull'appalto sono chiuse.
Per ulteriori lavori con il sito, leggi le informazioni di seguito.

Chi siamo

Motore di ricerca leader per gare e acquisti in Russia e nel mondo

  • Il più grande database di appalti e fonti di approvvigionamento in Russia e nel mondo
  • Newsletter giornaliera gratuita secondo le tue impostazioni
  • Informazioni sui vincitori delle gare nel formato che ti serve
  • Comoda visualizzazione e caricamento delle informazioni

Scegli noi

Iniziare

Registrazione al sito, dopodiché sono disponibili le seguenti funzionalità del sito:

  • Iscriviti alle mailing list gratuite per le tue frasi chiave
  • Visualizza annunci di gara
  • Esporta informazioni di riepilogo in formato Excel
  • Visualizza parte delle informazioni sui vincitori, fornitori e clienti delle gare

Registrazione

Per utilizzare tutte le funzioni del sito e visualizzare tutte le informazioni, devi registrare un account commerciale

  • Tariffa selezionata
  • Paga per l'accesso in uno qualsiasi dei modi possibili

Accesso completo
Blank photo projection necklace or bracelet Fonte: alibaba.com

22MM 100% pure Mulberry silk pillowcase,Oeko-tex silk pillow cover,charmeuse silk pillow case Fonte: alibaba.com

Замена фильтрующего элемента Parker/Zander 1070XP 1070XP4 Fonte: alibaba.com

Servicii de transport vaccinuri cu autovehicule frigorifice echipate corespunzator si operate de personal specializat Fonte: SEAP

Service Provider Firm for Hiring Vehicles and Transport Facilities Fonte: Central Procurement Technical Unit

Quotations are hereby invited for the following: Conduct the investigation on the parameters that have exceeded the required limit from the Surface and Underground Water Monitoring (focus on Boreholes) at Vereeniging Pumping Station. The scope of work shall include: - Determine the sources of the elevated parameters in the surface and groundwater monitoring (Boreholes); - Taking sample, analyse and submit report with reason why other parameters are out of the recommended limit; - Sample should be taken only for boreholes, not storm water; - Seven (7) boreholes are to be sampled. Four (4) of the boreholes are located inside the Rand Water Vereeniging Premises, other Three (3) are outside the premises about 800 meters away; - Service provider is expected to conduct monitoring for 5 (Five) consecutive months on 7 (Seven) boreholes; - The number of Samples to be taken should be 5 per borehole for each sampling event; - One borehole should be sampled 5 times to allow for the adequate volume for analysis; - Meaning for a month, it will be 7x5 samples giving us a total of 35 samples in a month; - The average depth of each borehole is about 30 meters, and the diameter is about 15cm; - The parameters to be analyzed are as follows: pH, Conductivity EC, Calcium Ca, Magnesium Mg, Sodium Na, Potassium K, Chloride Cl, Sulphate SO4, Aluminum Al, Iron Fe, Manganese Mn, Nitrate NO3, Ammonia NH4, Ortho-phosphate PO4, Boron B, Cadmium Cd, Cobalt Co, Chromium Cr, Copper Cu, Molybdenum Mo, Nickel Ni, Lead Pb, Vanadium V, Zinc Zn, Fluoride F, Total Silica, Odour, Alkalinity, Chemical Oxygen Demand [COD (mg/l)] , Total Hardness, Oil and Grease, Total Dissolved Solids, Suspended Solids, Oils & Grease; - Analysis shall be done at a SANAS accredited Lab, and proof of accreditation shall be provided; - Advise if Rand Water"s activities and process are contributing towards the exceedances of those parameters; - Advise what might be the cause of the exceedance from those parameters; - Determine what parameters should be analysed or included in the monitoring programme; - Advise if the current sampling locations/points are sufficient; - The investigation shall be carried out by competent Geo-hydrologist or personnel with any other related qualification. Fonte: ONLINE TENDERS